A dry type transformer manufacturer may be able to provide pre-production documentation, but the available product details do not confirm that a sample report comes as standard. They list factory acceptance testing (FAT), routine and type tests, and a full inspection before shipment. Buyers should verify whether a report based on a production sample is available and define its scope before approving the technical drawings.
The transformer is a three-phase, high-voltage dry-type unit built with epoxy resin cast or VPI construction. Its stated capacity range is 315–2500 kVA, with high-voltage options of 11, 27, 33, and 40.5 kV and a 0.4 kV low-voltage output. Cooling options are AN and AF. Listed applications include data and computing centers, as well as industrial and commercial complexes.
For quality control, the product information identifies FAT, routine testing, type testing, and a complete pre-shipment inspection. However, it does not specify a pre-production sample report, a physical sample, or the timing and format of any test records. These should be treated as separate deliverables until the manufacturer confirms them in writing.
During technical review, ask whether the manufacturer can issue a pre-production sample report and when it would be provided. Agree on the tests covered, acceptance criteria, reporting format, approval steps, and whether the results will apply to the final approved transformer configuration.
The product information references IEC 60076-11 and GB/T 1094.11-2022, while the quality-inspection entry mentions IEEE and IEC standards. Confirm which standards govern the specific project and which records will demonstrate compliance. It is also useful to establish whether the FAT, routine-test, type-test, and shipment-inspection results will each be documented and supplied.
Other listed design parameters include 50 or 60 Hz operation, Dyn11 or Yyn0 connection groups, F-class insulation rated at 155 °C, and a tapping range of ±2 × 2.5%. The stated delivery period is 45–60 working days after the deposit is received and the technical drawings are confirmed. Settling documentation expectations before drawing approval can help align the test plan with the project schedule.
The supplied company credentials include UDEM certificate M.2052.206.C132155, applicable to substations, transformers, and switchgear, and CNAS accreditation No. CNAS L16271 for testing an oil-immersed power transformer model. These credentials do not, by themselves, confirm that a pre-production sample report is included for this dry-type transformer.
Two cited projects describe the company’s broader power-equipment work: a Madagascar grid-renovation project involving two 63/35 kV, 25 MVA units, and a 110 kV indoor GIS project in Suriname with 40 intervals. They provide project context but do not establish a reporting commitment for this product.
| Item | What is stated | What to confirm |
|---|---|---|
| Pre-production sample report | Not expressly included in the product details | Availability, issue date, contents, and approval process |
| Factory acceptance testing | FAT is listed | Test scope and whether documented results will be provided |
| Routine and type tests | Both are listed | Applicable test items, standards, and acceptance limits |
| Pre-shipment inspection | Full inspection is listed | Inspection records supplied with the shipment |
| Transformer configuration | Three phase, 315–2500 kVA, with 11–40.5 kV high-voltage options | Project ratings and final approved drawings |
No. The listed provisions cover FAT, routine and type testing, and inspection before shipment, but do not explicitly promise a pre-production sample report.
Ask what FAT, routine-test, and type-test documentation is available, when it will be issued, and whether it applies to the approved transformer design and the project’s required standards.
Confirm the requirements during the technical review and before approving drawings. The stated 45–60 working-day lead time starts after the deposit and technical drawing confirmation.
The available information indicates that the manufacturer provides several forms of testing and inspection, but it does not confirm a standard pre-production sample report. Buyers should obtain written agreement on whether such a report can be supplied and define its contents alongside FAT, routine testing, type testing, and shipment-inspection records. The listed supply options include manufacturer, OEM and ODM, and turn-key project services; the minimum order quantity is one. For technical questions, contact support@vziman.com.
Zhejiang Vziman Electric Power Technology Co., Ltd. is the parent company of Zhejiang Vziman Electric Group Co., Ltd. The group focuses on research and development, manufacturing, and service for electrical power equipment, including transformers and switchgear. It reports a 10,000-square-meter factory and an R&D team of more than 30 senior electrical engineers and industrial designers. Its stated credentials include UDEM and CNAS, and its project portfolio includes utility and transmission-grid work.

REPORT